Follow
Meir Teitel
Title
Cited by
Cited by
Year
Low-Reynolds-number effects in a fully developed turbulent channel flow
RA Antonia, M Teitel, J Kim, LWB Browne
Journal of Fluid mechanics 236, 579-605, 1992
3001992
The effect of screened openings on greenhouse microclimate
M Teitel
Agricultural and Forest Meteorology 143 (3-4), 159-175, 2007
1452007
Sustainable greenhouse systems
G Vox, M Teitel, A Pardossi, A Minuto, F Tinivella, E Schettini
Sustainable agriculture: technology, planning and management 14, 2010
1432010
Effect of wind direction on greenhouse ventilation rate, airflow patterns and temperature distributions
M Teitel, G Ziskind, O Liran, V Dubovsky, R Letan
Biosystems Engineering 101 (3), 351-369, 2008
1372008
The effect of insect-proof screens in roof openings on greenhouse microclimate
M Teitel
Agricultural and Forest Meteorology 110 (1), 13-25, 2001
1242001
Natural ventilation of greenhouses: experiments and model
M Teitel, J Tanny
Agricultural and forest meteorology 96 (1-3), 59-70, 1999
1131999
Screenhouse microclimate and ventilation: an experimental study
J Tanny, S Cohen, M Teitel
Biosystems engineering 84 (3), 331-341, 2003
1092003
A comparison between pipe and air heating methods for greenhouses
M Teitel, I Segal, A Shklyar, M Barak
Journal of Agricultural Engineering Research 72 (3), 259-273, 1999
1001999
Wind driven ventilation of a mono-span greenhouse with a rose crop and continuous screened side vents and its effect on flow patterns and microclimate
M Teitel, O Liran, J Tanny, M Barak
Biosystems Engineering 101 (1), 111-122, 2008
972008
Energy saving in agricultural buildings through fan motor control by variable frequency drives
M Teitel, A Levi, Y Zhao, M Barak, E Bar-lev, D Shmuel
Energy and Buildings 40 (6), 953-960, 2008
942008
Air-flow patterns and heat fluxes in roof-ventilated multi-span greenhouse with insect-proof screens
E Shilo, M Teitel, Y Mahrer, T Boulard
Agricultural and Forest Meteorology 122 (1-2), 3-20, 2004
822004
SE—Structures and Environment: Vertical temperature and humidity gradients in a naturally ventilated greenhouse
Y Zhao, M Teitel, M Barak
Journal of Agricultural Engineering Research 78 (4), 431-436, 2001
772001
Using computational fluid dynamics simulations to determine pressure drops on woven screens
M Teitel
Biosystems engineering 105 (2), 172-179, 2010
752010
Pressure drop across insect-proof screens
M Teitel, A Shklyar
Transactions of the ASAE 41 (6), 1829-1834, 1998
721998
Airflow and heat flux through the vertical opening of buoyancy-induced naturally ventilated enclosures
J Tanny, V Haslavsky, M Teitel
Energy and Buildings 40 (4), 637-646, 2008
712008
Heat transfer in fully developed turbulent channel flow: comparison between experiment and direct numerical simulations
M Teitel, RA Antonia
International Journal of Heat and Mass Transfer 36 (6), 1701-1706, 1993
711993
Shading screens for frost protection
M Teitel, UM Peiper, Y Zvieli
Agricultural and forest meteorology 81 (3-4), 273-286, 1996
641996
Gradients of temperature, humidity and CO2 along a fan-ventilated greenhouse
M Teitel, M Atias, M Barak
Biosystems Engineering 106 (2), 166-174, 2010
632010
Comparison of measured and simulated flow through screens: Effects of screen inclination and porosity
M Teitel, D Dvorkin, Y Haim, J Tanny, I Seginer
Biosystems Engineering 104 (3), 404-416, 2009
632009
Effect of cyclic heating and a thermal screen on the nocturnal heat loss and microclimate of a greenhouse
M Teitel, M Barak, A Antler
Biosystems engineering 102 (2), 162-170, 2009
592009
The system can't perform the operation now. Try again later.
Articles 1–20