Beyond the blocking model to fit nanoparticle ZFC/FC magnetisation curves KL Livesey, S Ruta, NR Anderson, D Baldomir, RW Chantrell, D Serantes Scientific Reports 8 (1), 11166, 2018 | 118 | 2018 |
Ferromagnetic particles as magnetic resonance imaging temperature sensors JH Hankiewicz, Z Celinski, KF Stupic, NR Anderson, RE Camley Nature communications 7 (1), 12415, 2016 | 60 | 2016 |
Development of Ferrite-Based Temperature Sensors for Magnetic Resonance Imaging: A Study of NA Alghamdi, JH Hankiewicz, NR Anderson, KF Stupic, RE Camley, ... Physical review applied 9 (5), 054030, 2018 | 33 | 2018 |
Resonant frequencies of a binary magnetic nanowire KL Livesey, J Ding, NR Anderson, RE Camley, AO Adeyeye, MP Kostylev, ... Physical Review B—Condensed Matter and Materials Physics 87 (6), 064424, 2013 | 29 | 2013 |
Zinc doped copper ferrite particles as temperature sensors for magnetic resonance imaging JH Hankiewicz, N Alghamdi, NM Hammelev, NR Anderson, RE Camley, ... Aip Advances 7 (5), 2017 | 24 | 2017 |
An effective medium study of surface plasmon polaritons in nanostructured gratings using attenuated total reflection MH Tyboroski, NR Anderson, RE Camley Journal of Applied Physics 115 (1), 2014 | 24 | 2014 |
Attenuated total reflection study of bulk and surface polaritons in antiferromagnets and hexagonal ferrites: Propagation at arbitrary angles NR Anderson, RE Camley Journal of Applied Physics 113 (1), 2013 | 24 | 2013 |
Monolithic microwave nonlinear phase shifter BK Kuanr, NR Anderson, ZJ Celinski, RE Camley IEEE Magnetics Letters 6, 1-4, 2015 | 19 | 2015 |
Magnetic relaxation time for an ensemble of nanoparticles with randomly aligned easy axes: A simple expression AR Chalifour, JC Davidson, NR Anderson, TM Crawford, KL Livesey Physical Review B 104 (9), 094433, 2021 | 14 | 2021 |
Temperature-dependent magnetization in bimagnetic nanoparticles with antiferromagnetic interfacial exchange NR Anderson, RE Camley Physical Review B 94 (13), 134432, 2016 | 13 | 2016 |
Simulating the Self-Assembly and Hysteresis Loops of Ferromagnetic Nanoparticles with Sticking of Ligands NR Anderson, J Davidson, DR Louie, D Serantes, KL Livesey Nanomaterials 11 (11), 2870, 2021 | 12 | 2021 |
Planar magnetic devices for signal processing in the microwave and millimeter wave frequency range Z Celinski, IR Harward, NR Anderson, RE Camley Handbook of Surface Science 5, 421-457, 2015 | 8 | 2015 |
Multilayer magnetic waveguides: Optimizing nonreciprocal propagation in the 50–70 GHz range NR Anderson, RE Camley Journal of Applied Physics 116 (2), 2014 | 6 | 2014 |
Eta-quotients of prime or semiprime level and elliptic curves M Allen, N Anderson, A Hamakiotes, B Oltsik, H Swisher Involve, a Journal of Mathematics 13 (5), 879-900, 2020 | 4 | 2020 |
Exploration of Fermi-Pasta-Ulam Behavior in a Magnetic System J Lewis, RE Camley, NR Anderson Physical Review Letters 120 (16), 167203, 2018 | 3 | 2018 |
Field-dependent magnetic relaxation times of magnetic nanoparticle systems: analytic approximations supported by numerical simulations JC Davidson, NR Anderson, KL Livesey Physical Review B 110 (14), 144447, 2024 | 2 | 2024 |
Why do magnetic nanoparticles form messy clumps? Taking into account the bridging or sticking of ligands in simulations NR Anderson, DR Louie, D Serantes, KL Livesey arXiv preprint arXiv:1610.07678, 2016 | 2 | 2016 |
Probing materials with electromagnetic waves: from bulk materials to microstructures NR Anderson, RE Camley, KL Livesey Compendium on Electromagnetic Analysis: From Electrostatics to Photonics …, 2020 | 1 | 2020 |
Arthroscopic versus Open MTP Arthrodesis: A Biomechanical Comparison K Hunt, A Younger, R Fuld III, J Kelley, N Anderson, T Baldini Foot & Ankle Orthopaedics 2 (3), 2473011417S000209, 2017 | 1 | 2017 |
ATFL repair alone versus combined repairs of ATFL and CFL: A Biomechanical Comparison of Repair Techniques K Hunt, J Kelley, R Fuld III, N Anderson, T Baldini Foot & Ankle Orthopaedics 2 (3), 2473011417S000210, 2017 | 1 | 2017 |